Rotronic - IE-250/1

Manufacturer Rotronic
Part Number IE-250/1
Inner Code 3808603
Technical specification ROTRONIC BRAND HYGROCLIP IE-250/1 CAPACITIVE PROP
Weight 1

Please contact us to request a price quote for Rotronic - IE-250/1, or for any other model as well. We offer competitive prices, fast delivery and a wide products distribution network in the UK.


WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

Where can I buy IE-250/1 by Rotronic in United Kingdom?

You can purchase IE-250/1 by Rotronic from RADWARD LTD. We serve customers across United Kingdom, offering competitive prices and reliable service.

What is the price of the IE-250/1?

For customized pricing and availability, please fill out our contact form or give us a call. We are dedicated to providing solutions that align with your specific requirements.

Who is the official distributor or seller of Rotronic in United Kingdom?

While we are not the official distributor or seller of Rotronic in United Kingdom, we source our products from reliable channels and offer you original Rotronic equipment at competitive prices.

How can I access IE-250/1 catalogs, user manuals, technical documents, and PDFs?

You can access catalogs, user manuals, and technical documents for IE-250/1 on our website. Visit our resources section or contact us directly for specific documents.

Do you provide technical support for IE-250/1?

While we do not offer direct technical support, we can assist you in contacting the manufacturer to ensure you receive the support you need.

Rotronic-IE-250/1 price
4 / 5
(7)

More products of Rotronic

  • HF420-DB1XX2XX

    Transmitters for humidity and temperature 2x2 printed circuit design, Power supply: 10 ... 28 VDC, Duct mounting, vertical Mon t age, Sensor Dimensions: 208 x 15 mm, Output signals: OUT1: 4 ... 20 mA = 0 ... 100% RH, OUT2: 4 ... 20 mA = 0 ... 50 ° C.

  • HF420-DT1XX1XX

    Transmitters for humidity and temperature 2-wire operation, Power supply: 10 ... 28 VDC, Duct installation, Probe Dimensions: 208 x 15 mm, OUT1: 4 ... 20 mA = 0 ... 50 ° C.

  • HF432-DB1XX2XX

    Messumformer für Feuchte und Temperatur

  • HF531-DA3XX2BX

    Transmitter for temperature and dew point Channel version, 3/4-wire, 15 ... 40 VDC / 12 ... 28 VAC, vertical mounting, 1 M16x1.5 gland, Output signals: OUT1: 0 ... 20 mA = -40 ... 60 ° C, OUT2: 0 ... 20 mA = -50 ... 50 ° C (DP

  • HF532- DBA3X5XX

    Transmitters for humidity and temperature Channel version, 3/4-wire, vertical mounting, 15 ... 40 VDC / 12 ... 28 VAC, RS485 on terminals, 1 x M16 gland, Output signals: OUT1: 4 ... 20 mA = 0 ... 100% RH, OUT2: 4 ... 20 mA = 0 ... 100 ° C.

  • HF532-DB1XX1XX

    Messumformer für Feuchte und Temperatur

  • HF532-WBD6D5XX

    Transmitters for humidity and temperature Wall design, horizontal mounting, Included LCD display with operating panel, 15 ... 40 VDC / 12 ... 24 VAC, 4.3 wire that Output signals: OUT1: 4 ... 20 mA = 0 ... 100% RH, OUT2: 4 ... 20 mA = 0 ... 150 ° C.

  • HF532-WBD6X1XX

    transducer

  • HF532-WBD6X1XX

    Transmitter for humidity and temperature wall-mounted version, 3/4-wire, horizontal mounting, power supply 15 ... 40 VDC / 12 ... 28 VAC, connection: 1 M16x1.5 gland, output signals OUT1: 4 ... 20 mA = 0 ... 100% RH, OUT2: 4 ... 20 mA = 0 ... 150 ° C.

  • HF532-WBD6X5XX

    transducer

  • HF632 – DB 1 XX 21XX - obsolete, replacement HF732- PB1XX21XX

    transmitter, Power : 15 – 40 VDC / 12 - 28 VAC, OP.Range : -400… / + 60 oC, Out H : 0….100 % RH 4-20 mA, Out T : 0….+50oC 4-20 mA

  • HF732- PB1XX21XX

    Transmitters for humidity and temperature Channel model with 550 mm probe length, PPS trunk 15 mm, 3/4-wire version, IP65 aluminum die-cast housing, Power supply: 15 ... 40 VDC / 12 VAC ... 28, Connection: 1 M16x1.5 stainless steel nuts, Output signals: OUT1: 4 ... 20 mA = 0 ... 100% RH, OUT2: 4 ... 20 mA = 0 ... 50 ° C.

  • HF732-QBD6XSFXX

    Messumformer

  • HF732-QBD6XSFXX

    Transmitter for humidity and temperature channel design with 250 mm probe length, PPS trunk 25/15 mm, 3/4-wire version, IP65 die-cast aluminum casing, power supply 15 ... 40 VDC / 12 ... 28 VAC, connection: 7-pole plug tuchel, (+ supply signals), output signals OUT1: 4 ... 20 mA = 0 ... 100% RH, OUT2: 4 ... 20 mA = 0 ... 150 ° C.

  • HF732-QBD6XSFXX

    Transmitter for humidity and temperature channel design with 250 mm probe length, PPS trunk 25/15 mm, 3/4-wire version, IP65 die-cast aluminum casing, power supply 15 ... 40 VDC / 12 ... 28 VAC, connection: 7-pole plug tuchel, (+ supply signals), output signals OUT1: 4 ... 20 mA = 0 ... 100% RH, OUT2: 4 ... 20 mA = 0 ... 150 ° C.

  • HIYGROMER

    Moisture meter

  • HL-20D

    (Data logger for relative humidity and Temperature with display with integrated sensors, Display with backlight, Alarm via LED display, Battery status display, Function key: start / stop logging, Real-time function (RTC) Loop or start / stop storage mode, Measuring range: 0 ... 100% RH / 0 ... 50 ° C, Accuracy (23 ° C): ± 0.8% RH / ± 0.2 ° C, Repeatability: ± 0.3% RH / ± 0.05 ° C, Long term stability: <1% RH / 0.1 ° C / year, Calculations: dew or frost point, Log-interval: 5 seconds to 1 hour, Interface: UART to USB (via AC3006) Housing material: ABS, Dimensions: 130 x 72 x 32 mm, Weight: about 270 g).

  • HP 21

    Hand-held instrument with an integrated probe for humidity and temperature.

  • HP22-A

    Handmessgeräte HygroPalm 22 für austauschbare HygroClip2-Fühler

  • HP-22-SET

    Sensor module for humidity and temperature HC2-S; 1 calibration ER-15; 1 Humidity standard EA80-SCS; 1 extension cable E2-02A; 1 Service case AC1127

  • HP23-A

    Hand-held instrument for 2 Sensor Module HC-2 or 2 analog sensor inputs (for 0.1 VDC or 0:20 mA), 9 V battery, calculating Absolufeuchtewerten, real-time clock with battery backup, Probe adjustment directly Taupunktreferenz, remote control ungsfunktion for transmitters, application range unit: 0 ... 100% rh / -10 ... 60 ° C measuring ranges depending sensor, mini USB interface Stores up to 16,000 readings: Each data sets contains humidity, temperature, date, time, batch number and user ID number ...

  • HP23-AW-A

    (Aw or% rh and ° C) hand-held instrument for quick AW measurement for humidity and temperature, calculation of all psychrometric humidity values, including internal memory for 20,000 records with real-time clock, data-capture function, mini-USB port (UART), Application : 0 ... 1 aw (0 ... 100% rh) / -10 ... 60 ° C, precision: sensor-dependent, automatic determination of the equilibrium state, including AW-qUICK-function for fast measurement of water activity.

  • HP23-AW-A SET

    Portable Water Activity System

  • HT800

    humidity sensor

  • HTS11X

    Industrial transmitter with instructions HygroFlex 1 12-35VDC / 24VAC, 2 analog outputs, 1 digital sensor input.

  • HTS12 X

    out 1:HO... 100%RH 4-20ma out 2:TO...100C 4-20ma

Other Category Brands