P/N 106004 Type: Industrial OG-TI100-PVC Badger Meter Sales In United Kingdom

Manufacturer Badger Meter
Part Number P/N 106004 Type: Industrial OG-TI100-PVC
Inner Code 4449468
Description Pulse transmitter
Custom Code 90282000
Technical specification LM OG 1/2" BSP PVC 1.4305 Vectra Viton 1-35 l/min with reed contact 100 PPL Oval wheel meter type OG_TI_100 in PVC version Material and technical data Measuring principle: oval wheel counter Housing: PVC plastic Lid: 304 stainless steel Oval wheels: plastic Vectra (LCP plastic) O-ring: Viton Measuring range: 1-35 l/min Measurement accuracy: +/- 0.5% of reading Viscosity range: 1-2000mPas p-max: 10 bar t-max: 45°C Pulse output: through reed contact 100 pulses/ litres Installation length: 82 mm Connection: female thread R 1/2"
Weight 0.9

Please contact us to request a price quote for Badger Meter - P/N 106004 Type: Industrial OG-TI100-PVC, or for any other model as well. We offer competitive prices, fast delivery and a wide products distribution network in the UK.


WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

Where can I buy P/N 106004 Type: Industrial OG-TI100-PVC by Badger Meter in United Kingdom?

You can purchase P/N 106004 Type: Industrial OG-TI100-PVC by Badger Meter from RADWARD LTD. We serve customers across United Kingdom, offering competitive prices and reliable service.

What is the price of the P/N 106004 Type: Industrial OG-TI100-PVC?

For customized pricing and availability, please fill out our contact form or give us a call. We are dedicated to providing solutions that align with your specific requirements.

Who is the official distributor or seller of Badger Meter in United Kingdom?

While we are not the official distributor or seller of Badger Meter in United Kingdom, we source our products from reliable channels and offer you original Badger Meter equipment at competitive prices.

How can I access P/N 106004 Type: Industrial OG-TI100-PVC catalogs, user manuals, technical documents, and PDFs?

You can access catalogs, user manuals, and technical documents for P/N 106004 Type: Industrial OG-TI100-PVC on our website. Visit our resources section or contact us directly for specific documents.

Do you provide technical support for P/N 106004 Type: Industrial OG-TI100-PVC?

While we do not offer direct technical support, we can assist you in contacting the manufacturer to ensure you receive the support you need.

Badger Meter-P/N 106004 Type: Industrial OG-TI100-PVC price
4 / 5
(38)

More products of Badger Meter

  • LM OG-CND 

    for petrol, oil, digital and electronic counters, rotary platforms ½, flow. 0-28 I / min

  • LM OG-PND P114

    Product preset Max 120°F/50°C Min 20°F/-5°C 868 mhz

  • B102101

    Einbauzähler mit Impulsgeber für Schmieröl

  • M2000 AM DN50

    ELECTROMAGNETIC FLOW METER

  • MAGNETOFLOW TYP II DN 65 / PN 16

    Magnetic flowmeter with transmitter M1500 for full pipes.

  • MID 2-100/16-F/ST-WG-ML/HC-ST M15A SK1

    Type II DN 100 / PN 16 with amplifier M1500 for full pipes

  • MID M 1000 MIT FLANSCH DN 32 HARTGUMMI HASTELLOY C 24VDC

    Magnetic flowmeter Magneto Flow Type II DN 32 / PN 16 with transmitter for M2000 full pipes.

  • MN7

    schetchik jidkosti

  • MN80AAP-1

    MN SERİES,70-733 LPM 1200 KPA 3”/80MM BSP

  • MODEL RCDL M25

    BADGER METER RCDL DISC METERS POSITIVE DISPLACEMENT – NUTATING DISC

  • RCDL LCR

    Register with pulse output, Electronic counter LCR type with an LCD display and, pulse output above for OG-Baureihe.Anzeige 1: resettable totalizer or flow indication programmable, Format xxxx.x. Display 2: Non-resettable totalizer, 14 digits. Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA Protection: IP 64 For counter Size: M25-M35-M40-M70-M120-M170 Pulse output: NPN, MOSFET 40V / 2A Pulse factor: 0.01-99.99 Pulse length: 10ms (2ms, 20ms, 40ms) Ext.Stromversorg. : 8-24VDC Pulse output PPL: 0,01-0,1-1-10-100 Dosing control: 0.01 to 999.99 Preliminary circuit: from 0.00 to 99.99 Switching output: NPN, MOSFET 40V / 2A

  • RCDL LCR REGISTER MIT IMPULSAUSGANG U. STROMAUSGANG 4-20MA

    Electronic counter LCR type with an LCD display, Display 1: resettable totalizer or Flow display programmable, Format xxx.xx. Display 2: Non-resettable totalizer 14 digits. Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA

  • RCDL LCR REGISTER OHNE IMPULSAUSGANG

    Electronic counter LCR type with an LCD display, for the OG series Display 1: resettable totalizer or Flow display programmable, format xxxx.x Display 2: Non-resettable totalizer 14 digits Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA Protection: IP 64

  • RCDL M25

    3/4 "or 1" PPO Viton without pulse, fluid meter RCDL M25 without construction. Material and technical data: Housing: Nylon Measuring chamber: Noryl (PPO) O-rings: Viton Measuring range: 1-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: 50 ° C Connection: R 3/4 "or R 1" Installation length: 190 mm Installation position: horizontal, standing

  • RCDL M25 1"

    Vectra Viton pulse PFT-2 reed contact Liquid meter RCDL M25 without construction. Materials and technical data: Housing: Bronze Measuring chamber: Vectra O-rings: Viton Measuring range: 3-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: ° C Connection: R 1 "outside Installation length: 190 mm Installation position: horizontal, standing 604011 Pulse PFT-2 reed contact about 52 PPL

  • RCDL M25 3/4" ODER 1" PPO VITON OHNE IMPULSGEBER

    (Liquid meter RCDL M25 without Construction. Material and technical data: Housing: Nylon Measuring chamber: Noryl (PPO) O-rings: Viton Measuring range: 1-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: 50 ° C Connection: R 3/4 "or R 1" Installation length: 190 mm Installation position: horizontal, vertical)

  • RCDL M25, WITH PULSE- TRANSMITTER PFT-1E - 52,4 PULSE/LITER SETUP

    Housing : Bronze Chamber : Noryl (PPO) O-Rings : Buna Flowrange : 1-100 l/min Accuracy : +/- 1,5 % of value p-max : 10 bar t-max : 50 °C Connection : Threads 1" male Laylength : 190mm Pulsoutput : Open Collector NPN Scale Factor : 0.00001 to 0.9999 Supply : 12-24 VDC Pulsoutput : S/N : Part-Nr. 141158

  • KT M2000 50

    MID M 2000 mit Flansch DN 50 1.4571

  • 106126

    Oval wheel counter

  • PN : MID M 1000, Type : Typ ModMAG M1000

    magnetic inductive flowmeter

  • 7500P

    Electromagnetic Flow Meter

  • XMT-DS-00738

    Pulse Flow meter

Jenama Kategori Lain